Category: Precast

Adjustable clamp 550 for temporary edge protection on concrete wall at construction site UK

Precast concrete walls and beams

Adjustable clamp 550 for temporary edge protection on concrete wall at construction site UK

Pre-casting concrete elements allows for inclusion of cast-in components to support the temporary edge protection system needed to erect the structure. If edge protection is needed in wall or beam elements, cast-in anchors can be inserted into the formwork. If the attachment point is on the side of the sections, our Vertical bracket (product code 912118) can be installed. If it’s on top of the sections our Post foot (product code 912105) can be used instead as a bracket for posts and steel mesh barriers.

Socket with Rebar 400 mm is an expendable socket that is embedded into slabs or beams with a minimum depth of 500 mm. The Post socket sits flush with the top of the concrete and it is supplied with a protective plastic cap to prevent concrete ingress.

If anchoring is to be avoided, Adjustable clamp 300 or 550 can be installed on site before the units are lifted into position.

SafetyRespect offer technical support and will provide detailed information to your specific criteria.

PRODUCTS
• Vertical bracket
• Post foot
• Socket base
• Socket with rebar 400 mm
• Clamp 300
• Clamp 550
• Post 1,3 m
• Barrier 1,3, 2,6
• Cast protection for Post foot
• Cast protection for Socket base

Collective edge protection at precast concrete walls and beams at construction site UK

Adjustable clamps for edge protection on construction sites

 

Edge protection precast wallsPrecast socket wall

Temporary edge protection with precast socket on construction site in UK

Omnia floor slabs

precast_socket_safetyrespect_5330c

Our Precast socket is designed to be casted into precast concrete slabs right at the concrete factory. This provide an easier, faster and safer mounting of temporary edge protection at the construction site.

An Omnia flooring slab is a reinforced precast concrete slab which incorporates a triangular lattice girder that is attached to a lower layer of reinforcement. The lattice girder is manufactured using high strength steel wire which binds with in-situ concrete which is poured onto it.

By casting a Precast socket (product code 911108) into the lower slab means that temporary edge protection can be installed onto the slab before it is lifted into position allowing rebar installation and concrete placing onto the slabs within a collectively protected work area.

Precast sockets are fixed to rebar before the lower portion concrete is cast. A cut length of Protective sleeve (product code 911107) is inserted onto the Precast socket, which forms a 50 mm diameter hole around the Post and allows extraction when temporary edge protection is no longer required.

The Precast socket has an integrated post lock. Post 1,3 m and Barrier 2,6 are installed either before or after the prefabricated element is lifted in place. The Barriers can easily be lifted to the desired height when casting. No tools are needed.

PRODUCTS
• Precast socket
• Protection sleeve for Precast socket
• Post 1,3 m
• Barrier 1,3, 2,6
• Frame barrier alu 1,3, 1,95, 2,6
• Frame barrier holder
• Adjustable link bar

precast_socket_safetyrespect_2082x

precast socket temporary edge protection concret constructionprecast_socket_safetyrespect_5344c

precast_socket_safetyrespect_5344

Frame barrier edge protection

 

Collective edge protection for Exclusion zone at construction site in UK

Freestanding edge protection

blocking_safetyrespect_7073c

When installing prefabricated concrete slabs a movable edge protection is required for safe blockage for other construction personnel. For this the Ground support plate is used together with Socket base, Post 1,3 m and Barrier 2,6. The Barriers then work as effective and safe blockage while the installation of prefabricated concrete slabs is carried out by workers with personal fall protection equipment.

PRODUCTS
• Ground support plate
• Socket base
• Post 1,3 m
• Barrier 1,3, 2,6
• Personal fall protection equipment

blocking_safetyrespect_5548

blocking_safetyrespect_7073

Temporary edge protection on concrete floor slabs at construction site in UK

Precast concrete floor slabs

Temporary edge protection on concrete floor slabs at construction site in UK

Pre-casting concrete elements allows for inclusion of cast-in components to support the temporary edge protection system needed to erect the structure. If edge protection is needed on top of the slab, anchor sockets can be cast to support a Post foot (product code 912105). For side of slab positioning cast-in anchors will support Vertical brackets (product code 912118).

Omnia slabs can be delivered with Precast socket (product code 911108) projecting from the top of the bottom concrete layer.

Socket with Rebar 400 mm is an expendable socket that is embedded into slabs or beams with a minimum depth of 500 mm.

If anchoring is to be avoided, Adjustable clamps 300 or 550 can be installed on site before the units are lifted into position.

In the brackets our Post 1,3 m is installed and thereafter Barrier 2,6. The Barrier can be raised in one simple operation on the post up to a height of 310 mm above the floor structure, without decreased safety. This creates conditions for joint grouting, casting and other common work tasks without any need of uninstalling the edge protection.

SafetyRespect offer technical support and will provide a schedule of the equipment required to protect your door openings.

PRODUCTS
• Post foot
• Socket base
• Precast socket
• Socket with rebar 400 mm
• Clamp 300
• Clamp 550
• Post 1,3 m
• Barrier 1,3, 2,6
• Cast protection for Post foot
• Cast protection for Socket base

Temporary edge protection on concrete floor slabs at construction site in UK

Post foot edge protection bracket for concrete_slab egde constructions UK

standard_system_safetyrespect_0136c

Adjustable Clamp 300 as attachment for collective edge protection on concrete slab floor

standard_system_safetyrespect_0114c

Temporary edge protection with precast socket on construction site in UK

Concrete casting in site

Casting in site

Concrete casting in site

With a structure framework cast-in-site there is the possibility of designing attachment points for the edge protection. Socket w rebar with integrated post lock, for example, can be cast into the wall tops in, for instance, house gables, lift- and stair shafts. After this Post 1,3 m and Barrier are installed. Vertical brackets can be installed on the formwork as attachments, followed by Post 1,3 m and Barrier.

In order to be able to build external panel walls from inside the slab Balcony bracket 10 degrees can be installed as an attachment, which gives an inclination of the edge protection by approximately 10 degrees. For other requirements of edge protection such as stairs, window openings, etc., there are several solutions that can be designed and cast in order to facilitate installation of edge protection and to create safer working sites.

PRODUCTS
• Socket w rebar
• Balcony bracket 10 degrees
• Balcony bracket
• Vertical bracket
• Post 1,3 m
• Barrier 1,3, 1,95, 2,6

casting_in_site_safetyrespect_04

socket_w_rebar_safetyrespect_0203

At the wall tops Socket W Rebar, with integrated post lock can be cast as attachments for edge protection.