Tag: catch fan

VT scaffold fix

Scaffold fix

VT scaffold fix

The Scaffold fix for Catch fan is for use on scaffolds.

• 2.4 kg
• EN 1263
• Hot-dip galvanised (HDG)
• 270 x 215 mm

Art. No. 5050004

Product sheet

VT Wallfix

Wall fix

VT Wallfix

The Wall fix for Catch fan is for use on vertical surfaces such as walls.

• 4.7 kg
• EN 1263
• Hot-dip galvanised (HDG)
• 575 x 120 mm

Art. No. 5050003_W

Product sheet

VT Catch fan

VT Catch fan

 

VT Slabfix

Slab fix

VT Slabfix

The Slab fix for Catch fan is for use on horizontal surfaces at the slab edge.

• 4.7 kg
• EN 1263
• Hot-dip galvanised (HDG)
• 430 x 270 mm

Art. No. 5050003_S

Product sheet

VT Catch fan

VT Catch fan

 

VT Catch fan 6m

Catch fan 6m

VT Catch fan 6m

Our Catch fans provide reliable protection against falling objects during the construction period and catch workers who have accidents. Made up of just a few components, the Catch fan not only protects construction site personnel, but also the public, depending on the situation and application.

Due to the 3 m cantilever, the Catch fan in front of the building creates an appropriate protection zone against falling objects, such as materials, tools or construction debris. In addition, it is intended to cushion falls of injured construction site personnel and to enable rescue.

Due to its application possibilities, the Catch Fan can be adapted to a wide variety of construction situations. It can also be used in confined spaces without any problems, as the Catch Fan can
be folded up towards the façade and be secured, e.g. to allow material transport near the ceiling edge.

The safety net has a mesh size of 60×60 mm. The standard scope of delivery of the Catch Fan also includes a fine-mesh net with a mesh size of 20×20 mm. It is firmly connected to the safety net to protect against falling small objects. On customer request, the net structure can additionally be provided with a third layer of a 2×3 mm dust protection net.

SAFETY REQUIREMENTS
Once a year, the Catch Fans in use must be inspected. The main focus here is on the material safety of the net structures. For this purpose, one of the test threads attached to the Catch Fan net must be sent to Vivatec or to an accredited testing institute. The regular safety checks on the construction site and the checks after load impacts remain unaffected by this requirement.

• Net surface of 18 m2
• 91 kg
• EN 1263
• Hot-dip galvanised (HDG) / aluminium
• 6000 x 3000 cm

Art. No. 5056000

Product sheet

VT Catch fan

VT Catch fan

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan lifted at construction site

VT Catch fans at construction site

VT Catch fan

VT Catch fan

VT Catch fan 4m

Catch fan 4m

VT Catch fan 4m

Our Catch fans provide reliable protection against falling objects during the construction period and catch workers who have accidents. Made up of just a few components, the Catch fan not only protects construction site personnel, but also the public, depending on the situation and application.

Due to the 3 m cantilever, the Catch fan in front of the building creates an appropriate protection zone against falling objects, such as materials, tools or construction debris. In addition, it is intended to cushion falls of injured construction site personnel and to enable rescue.

Due to its application possibilities, the Catch Fan can be adapted to a wide variety of construction situations. It can also be used in confined spaces without any problems, as the Catch Fan can
be folded up towards the façade and be secured, e.g. to allow material transport near the ceiling edge.

The safety net has a mesh size of 60×60 mm. The standard scope of delivery of the Catch Fan also includes a fine-mesh net with a mesh size of 20×20 mm. It is firmly connected to the safety net to protect against falling small objects. On customer request, the net structure can additionally be provided with a third layer of a 2×3 mm dust protection net.

SAFETY REQUIREMENTS
Once a year, the Catch Fans in use must be inspected. The main focus here is on the material safety of the net structures. For this purpose, one of the test threads attached to the Catch Fan net must be sent to Vivatec or to an accredited testing institute. The regular safety checks on the construction site and the checks after load impacts remain unaffected by this requirement.

• Net surface of 12 m2
• 67 kg
• EN 1263
• Hot-dip galvanised (HDG) / aluminium
• 4000 x 3000 mm

Art. No. 5054000

Product sheet

VT Catch fan

VT Catch fan

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan lifted at construction site

VT Catch fans at construction site

VT Catch fan

VT Catch fan

VT Catch fan

Catch fans on walls

VT Catch fan

Catch fan for walls is a complement to our temporary edge protection system and is used to catch falling material and objects (not people) that may constitute a risk for injuries to people and damage to objects. This catch fan is adapted to be installed on a vertical surface without any need of cranes and with the edge protection mounted freestanding on the working area.

PRODUCTS
• Catch fan 4m
• Catch fan 6m
• Wall fix

VT Catch fan lifted at construction site

VT Catch fan

Catch fans on slab edges

VT Catch fan

Catch fan for slabs is a complement to our temporary edge protection system. The fan is a collective safety measure that catch and contain falling objects where access is required in the immediate vicinity of a high rise structure. The fan can be installed without any need of cranes and this version is designed to be installed on concrete floor slabs edges.

Catch fans are designed to fit directly vertically or horizontally onto building frames or scaffolding structures using a range of accessories. They are for and six meters wide with a three meter overhang, and fixed directly to the top of the slab using reusable anchor bolts. The fans are compact, lightweight and transportable between work areas without the use of a crane.

Catch fans are installed up to six meters below the working area and they will catch and absorb the energy of falling object or debris, ensuring that they don’t bounce out of the net. They can also protect the public in, for example, city environments. A fine mesh layer is fixed to the net to catch smaller objects. Fallen objects are retrieved by simply folding the net to gain access. They can easily be moved and adapted throughout the construction project. Easy to fold to a vertical position in order not to interfere with cranes.

PRODUCTS
• Catch fan 4m
• Catch fan 6m
• Slab fix

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan lifted at construction site

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fan on slab at construction site

VT Catch fans at construction site

VT Catch fan

VT Catch fan