Temporary edge protection on concrete floor slabs at construction site in UK

Precast concrete floor slabs

Temporary edge protection on concrete floor slabs at construction site in UK

Pre-casting concrete elements allows for inclusion of cast-in components to support the temporary edge protection system needed to erect the structure. If edge protection is needed on top of the slab, anchor sockets can be cast to support a Post foot (product code 912105). For side of slab positioning cast-in anchors will support Vertical brackets (product code 912118).

Omnia slabs can be delivered with Precast socket (product code 911108) projecting from the top of the bottom concrete layer.

Socket with Rebar 400 mm is an expendable socket that is embedded into slabs or beams with a minimum depth of 500 mm.

If anchoring is to be avoided, Adjustable clamps 300 or 550 can be installed on site before the units are lifted into position.

In the brackets our Post 1,3 m is installed and thereafter Barrier 2,6. The Barrier can be raised in one simple operation on the post up to a height of 310 mm above the floor structure, without decreased safety. This creates conditions for joint grouting, casting and other common work tasks without any need of uninstalling the edge protection.

SafetyRespect offer technical support and will provide a schedule of the equipment required to protect your door openings.

PRODUCTS
• Post foot
• Socket base
• Precast socket
• Socket with rebar 400 mm
• Clamp 300
• Clamp 550
• Post 1,3 m
• Barrier 1,3, 2,6
• Cast protection for Post foot
• Cast protection for Socket base

Temporary edge protection on concrete floor slabs at construction site in UK

Post foot edge protection bracket for concrete_slab egde constructions UK

standard_system_safetyrespect_0136c

Adjustable Clamp 300 as attachment for collective edge protection on concrete slab floor

standard_system_safetyrespect_0114c

Temporary edge protection with precast socket on construction site in UK

Precast socket wall

Precast socket wall

Precast socket wall

The precast socket wall (product code 911200) is inserted and tied to the reinforcement bars of a wall pour so that temporary edge protection posts can be inserted into them. When working with precast concrete wall panels this means that the temporary edge protection system can be installed unto the top of the wall sections before they are lifted into place.

The Precast socket wall is manufactured with a post lock inside the sleeve which retains the edge protection post preventing accidental uplift or removal. It is also pre-fitted with a protective cap to prevent concrete ingress.

This component is designed to eliminate concrete drilling and the need to work at height by installing the temporary edge protection on the ground in turn reducing installation time. Precast Socket wall is also suitable for insitu wall formwork and floor slabs. Overall length is 450 mm with four horizontal bars for tying into rebar.

• Length 450 mm.
• Integrated post lock.
• Delivered with plastic cover.
• Weight 1,8 kg.

Art. No. 911200